What are bathroom electrical zones?
Bathroom electrical zones are areas around your bath and shower, set out in BS 7671, the UK wiring regulations, that control what electrical equipment can go where. The closer to the water, the stricter the rules, from waterproof low-voltage fittings inside the bath to ordinary fittings well away from it.
Knowing the zones helps you plan a new bathroom properly, so your lights, fan, shaver socket and towel rail are all in the right place. This guide explains each zone, what’s allowed and when you need an electrician.
Pick an item to see where it’s allowed
Choose something you’d like in your bathroom, and the zones where it can go light up.
What’s allowed in each of the bathroom electrical zones
A quick reference for planning lights, fans and sockets.
| Item | Zone 0 | Zone 1 | Zone 2 | Outside the zones |
|---|---|---|---|---|
| Lights | Only 12V SELV, IPX7 | IPX4 minimum | IPX4 minimum | Any suitable fitting |
| Extractor fan | No | Yes, IPX4 and suitable for the zone | Yes, IPX4 | Yes |
| Shaver socket | No | No | Yes, if out of direct spray | Yes |
| Standard socket | No | No | No | Only 3 m or more from zone 1 |
| Light switch | No | Pull-cord only | Pull-cord only | Yes |
| Electric shower | No | Yes, on its own circuit | Yes | Not applicable |
Planning a new bathroom? We’ll wire it to the zone rules and certify the work.
Bathroom electrical zones explained
Zone 0 is the inside of the bath or shower tray. Zone 1 is the space directly above it, up to 2.25 m from the floor, or up to the highest fixed shower head if that’s higher. Zone 2 then extends 0.6 m out from the edge of zone 1.
Anything beyond these areas is outside the zones. However, the whole bathroom is still a special location, so every circuit serving it must have 30mA RCD protection.
What IPX4 and IP65 mean
The IP rating shows how well a fitting keeps out solids and water. The second number is the water rating: 4 means protected against splashing, 5 against water jets and 7 against temporary immersion.
So IPX4 is the minimum in zones 1 and 2, while IP65 is a popular choice for shower lights, because it’s also rated for water jets.
Do you need an electrician for bathroom electrics?
In England, most electrical work within the bathroom zones is notifiable under Part P, as is any new circuit, such as one for an electric shower. Therefore, it should be done by a registered electrician who can certify it.
Replacing a fan or light like for like may not be notifiable, but it still has to meet the zone rules. If you’re fitting a fan, see our extractor fan installation service.
Bathroom electrical zones checklist for a refit
When planning a new bathroom, make sure:
- Lights and fans in zones 1 and 2 are rated at least IPX4
- No standard sockets are within 3 m of zone 1
- Switches are outside the zones, or you use a pull-cord switch
- Every circuit serving the bathroom has 30mA RCD protection
- An electric shower has its own correctly sized circuit
- Finally, the work is certified by a registered electrician
For lighting problems, see our guides on a light switch not working and LED lights flickering.
How we wire a bathroom to the zone rules
We follow the same three steps on every bathroom.
We plan the layout
We mark out the zones with you and agree where the lights, fan, shaver socket and switches will go.
We install
Then we install IP-rated fittings, RCD protection and any new circuits, ideally before the walls are tiled.
We test and certify
Finally, we test everything and give you the certificates, notifying Building Control where needed.
Bathroom electrical zones: FAQs
Do bathroom electrical zones allow a plug socket?
Only if it’s at least 3 m from the edge of zone 1, which rules it out in most UK bathrooms. A shaver socket is allowed closer, in zone 2.
What IP rating do bathroom lights need?
At least IPX4 in zones 1 and 2. Many people choose IP65 for lights directly above the shower.
Where can a light switch go in a bathroom?
Ordinary switches must be outside the zones, which often means outside the bathroom door. Inside, a pull-cord switch is the usual choice.
Does a bathroom need RCD protection?
Yes. Every circuit serving a room with a bath or shower must have 30mA RCD protection.
Can an extractor fan go above the shower?
Yes, if it’s rated at least IPX4 and suitable for zone 1. In fact, that’s often the best place for it.
How much does it cost to wire a new bathroom?
It depends on the lights, fan, shower and any new circuits. Send us your plans or a few photos on WhatsApp, and we’ll give you a free quote.
Planning a new bathroom?
We wire bathrooms to the zone rules across London, from IP-rated lighting to extractor fans and shower circuits. See our extractor fan installation service, or message us for a free quote.
Speak to a London electrician today
Call, email or WhatsApp us for a free quote. For emergencies, we answer 24/7.
Get a free quote from a London electrician
Tell us what you need and roughly where you are, and we’ll get back to you with a free quote, usually within 12 hours. Photos of the job always help.
Rather talk it through? Call us on 07447 569653 or send us a message on WhatsApp.
We’re NAPIT-accredited (No. 65117), and every job comes with the right certificate.